Logo image
A Noninvasive Blood-based Combinatorial Proteomic Biomarker Assay to Detect Breast Cancer in Women over age 50 with BI-RADS 3, 4, or 5 Assessment
Journal article   Peer reviewed

A Noninvasive Blood-based Combinatorial Proteomic Biomarker Assay to Detect Breast Cancer in Women over age 50 with BI-RADS 3, 4, or 5 Assessment

Meredith C Henderson, Michael Silver, Quynh Tran, Elias E Letsios, Rao Mulpuri, David E Reese, Ana P Lourenco, Joshua LaBaer, Karen S Anderson, Josie Alpers, …
Clinical cancer research, Vol.25(1), pp.142-149
01/01/2019
PMID: 30185421

Abstract

Adult Aged Biomarkers, Tumor - blood Biopsy Breast - diagnostic imaging Breast - metabolism Breast - pathology Breast Neoplasms - blood Breast Neoplasms - diagnostic imaging Breast Neoplasms - genetics Breast Neoplasms - pathology Female Humans Mammography Middle Aged Proteomics
With improvements in breast cancer imaging, there has been a corresponding increase in false-positives and avoidable biopsies. There is a need to better differentiate when a breast biopsy is warranted and determine appropriate follow-up. This study describes the design and clinical performance of a combinatorial proteomic biomarker assay (CPBA), Videssa Breast, in women over age 50 years. A BI-RADS 3, 4, or 5 assessment was required for clinical trial enrollment. Serum was collected prior to breast biopsy and subjects were followed for 6-12 months and clinically relevant outcomes were recorded. Samples were split into training (70%) and validation (30%) cohorts with an approximate 1:4 case:control ratio in both arms. A CPBA that combines biomarker data with patient clinical data was developed using a training cohort (469 women, cancer incidence: 18.5%), resulting in 94% sensitivity and 97% negative predictive value (NPV). Independent validation of the final algorithm in 194 subjects (breast cancer incidence: 19.6%) demonstrated a sensitivity of 95% and a NPV of 97%. When combined with previously published data for women under age 50, Videssa Breast achieves a comprehensive 93% sensitivity and 98% NPV in a population of women ages 25-75. Had Videssa Breast results been incorporated into the clinical workflow, approximately 45% of biopsies might have been avoided. Videssa Breast combines serum biomarkers with clinical patient characteristics to provide clinicians with additional information for patients with indeterminate breast imaging results, potentially reducing false-positive breast biopsies.

Details

Logo image