Biomechanical evaluation of coracoid tunnel size and location for coracoclavicular ligament reconstruction
Journal article   Peer reviewed

Biomechanical evaluation of coracoid tunnel size and location for coracoclavicular ligament reconstruction

Sean T. Campbell, Nathanael D. Heckmann, Sang-Jin Shin, Lawrence C. Wang, Mallika Tamboli, Joel Murachovsky, James E. Tibone and Thay Q. Lee
Arthroscopy - Journal of Arthroscopic and Related Surgery, Vol.31(5)
2015

Abstract

Acromioclavicular Joint Adult Aged Biomechanical Phenomena Cadaver Female Humans Ligaments, Articular Male Middle Aged Orthopedic Procedures Reconstructive Surgical Procedures Scapula Suture Techniques Sutures adult aged Article biomechanics bone strength cadaver clinical article controlled study coracoclavicular ligament reconstruction coracoid base coracoid process coracoid tunnel location coracoid tunnel size cortical button fixation cyclic loading female human ligament surgery male musculoskeletal system parameters scapula surgical technique trabecular bone acromioclavicular joint biomechanics devices injuries ligament middle aged orthopedic surgery pathophysiology plastic surgery procedures surgery suture suturing method
Purpose The purpose of this study was to determine the effect of coracoid tunnel size and location on the biomechanical characteristics of cortical button fixation for coracoclavicular ligament reconstruction. Methods Thirteen matched pairs of cadaveric scapulae were used to determine the effects of coracoid tunnel size, and 6 matched pairs were used to determine the effects of coracoid tunnel location. For tunnel size, a 4.5-mm hole was drilled in the base of the coracoid of one scapula and a 6-mm hole was drilled in the contralateral scapula. For tunnel location, 2 holes were drilled: (1) The first group received a hole centered in the coracoid base and a hole 1.5 cm distal from the first, along the axis of the coracoid. (2) The second group received holes that were offset anteromedially from the first set of holes (base eccentric and distal eccentric). A cortical button-suture tape construct was placed through each tunnel, and constructs were then loaded to failure. Results For tunnel size specimens, load at ultimate failure was significantly greater for the 4.5-mm group compared with the 6-mm group (557.6 ± 48.5 N v 466.9 ± 42.2 N, P <.05). For tunnel location, load at ultimate failure was significantly greater for the centered-distal tunnel group compared with the eccentric-distal group (538.1 ± 70.2 N v 381.0 ± 68.6 N, P <.05). Conclusions A 4.5-mm tunnel in the coracoid provided greater strength for cortical button fixation than a 6-mm tunnel. In the distal coracoid, centered tunnels provided greater strength than eccentric tunnels. Clinical Relevance When performing cortical button fixation at the coracoid process for coracoclavicular ligament reconstruction, a 4.5-mm tunnel provides greater fixation strength than a 6-mm tunnel. The base of the coracoid is more forgiving than the distal coracoid regarding location. © 2015 Arthroscopy Association of North America.

Metrics

4 Record Views

Details

Logo image