Logo image
Radiocapitellar Contact Characteristics After Osteochondral Defect Repair Using a Novel Hybrid Reconstructive Procedure
Journal article   Open access   Peer reviewed

Radiocapitellar Contact Characteristics After Osteochondral Defect Repair Using a Novel Hybrid Reconstructive Procedure

Derek T. Dee, Victor T. Hung, Connor J. Schamblin, Gregory M. Lupica, Hunter R. Hitchens, Michelle H. McGarry and Thay Q. Lee
Orthopaedic Journal of Sports Medicine, Vol.10(3)
2022

Abstract

hydroxyapatite aged allograft Article biomechanics bone radiography bone structure clinical article debridement female finite element analysis follow up human humerus kinematics knee function male osteochondritis simulation skin graft subchondral bone tendon graft viscoelasticity
Background: Many procedures to reconstruct osteochondral defects of the elbow radiocapitellar (RC) joint lack versatility or durability or do not directly address the subchondral bone structure and function. Purpose/Hypothesis: To biomechanically characterize the RC joint contact area, force, pressure, and peak pressure before and after reconstruction of osteochondral defects using a novel hybrid reconstructive procedure. It was hypothesized that the procedure would restore the contact characteristics to the intact condition. Study Design: Controlled laboratory study. Methods: A total of 10 cadaveric elbows (mean age 67 ± 2.7 years) were dissected to isolate the humerus and radial head. RC contact area, contact force, mean contact pressure, and peak contact pressure were measured with the elbow at 45° of flexion and neutral forearm rotation at compressive loads of 25, 50, and 75 N. Osteochondral defects 8 and 11 mm in diameter were created at the center of the capitellum; the defects were then reconstructed with a titanium fenestrated threaded implant, countersunk in the subchondral bone, with an acellular dermal matrix allograft sutured in place on top of the implant. Five conditions (intact, 8-mm defect, 8-mm repair, 11-mm defect, and 11-mm repair) were tested and results were compared using repeated-measures analysis of variance. Results: Both 8- and 11-mm defects significantly increased RC mean contact pressure at all compressive loads (P ≤.008) and significantly increased peak contact pressure at compressive loads of 50 and 75 N (P <.002) compared with the intact condition. Repair of the 8-mm defect significantly decreased RC mean contact pressure at 25- and 50-N loads (P ≤.009) and significantly decreased peak contact pressure at 50- and 75-N loads (P ≤.035) compared with the defect condition. Repair of the 11-mm defect decreased mean contact pressure significantly at all compressive loads (P ≤.001) and peak contact pressure at 50- and 75-N loads (P <.044) compared with the defect condition. Conclusion: RC joint contact pressure was restored to intact conditions while avoiding increased peak contact pressure or edge loading after repairing osteochondral defects related to osteochondrosis with a novel hybrid reconstruction technique. Clinical Relevance: This hybrid procedure that addresses the entire osteochondral unit may provide a new treatment option for osteochondral defects. © The Author(s) 2022.
url
https://doi.org/10.1177/23259671221083582View
Published (Version of record) Open

Metrics

6 Record Views

Details

Logo image