Superior Capsule Reconstruction With Fascia Lata Allograft Has Initial Stiffness and Ultimate Load Comparable to the Native Shoulder Superior Capsule: A Cadaveric Biomechanical Study
Journal article   Peer reviewed

Superior Capsule Reconstruction With Fascia Lata Allograft Has Initial Stiffness and Ultimate Load Comparable to the Native Shoulder Superior Capsule: A Cadaveric Biomechanical Study

Nicholas DeBellis, James E. Tibone, John Manning, Victor Hung, Michelle H. McGarry, Gregory J. Adamson and Thay Q. Lee
Arthroscopy - Journal of Arthroscopic and Related Surgery, Vol.39(1)
2023

Abstract

Allografts Biomechanical Phenomena Cadaver Fascia Lata Humans Rotator Cuff Injuries Shoulder Shoulder Joint abduction allograft article controlled study fascia lata human microcapsule rigidity shoulder allograft biomechanics cadaver fascia lata rotator cuff injury shoulder transplantation
Purpose: The purpose of this study was to compare the biomechanical characteristics of a fascia lata superior capsule reconstruction (FL-SCR) to the native superior capsule. Methods: The native superior capsule of 8 cadaveric shoulders was tested with cyclic loading from 10 to 50 N for 30 cycles in 20° of glenohumeral abduction followed by load to failure at 60 mm/min. Following native superior capsule testing, FL-SCR was performed, which was tested as described for the native capsule. Paired t test was used for statistical analyses with P < .05 for significance. Results: The stiffness for cycle 1 to 50 N was significantly higher for the native superior capsule compared to the FL-SCR (P = .001). By cycle 30, the stiffness between the two was not statistically different (P = .734). During load to failure, the initial stiffness to 2 mm for the FL-SCR and the native superior capsule was not statistically different (P = .262). The linear stiffness and yield load of the native superior capsule were significantly greater than that of the FL-SCR (94.5 vs 28.0 N/mm, P = .013; 386.9 vs 123.8 N, P = .029). There was no significant difference in ultimate load between the native superior capsule and the FL-SCR (444.9 vs 369.0 N, P = .413). Conclusions: FL-SCR has initial stiffness and ultimate load similar to the native superior capsule. Clinical Relevance: The biomechanical properties of FL allograft make it an appealing option as a graft choice for superior capsule reconstruction. © 2022 Arthroscopy Association of North America

Details

Logo image