Abstract

Adolescent Child Child, Preschool Clinical Decision-Making Clinical Protocols Decision Support Techniques Female Guideline Adherence Humans Infant Infant, Newborn Male Practice Guidelines as Topic Practice Patterns, Physicians' Prospective Studies Respiration, Artificial Respiratory Distress Syndrome, Adult United States water acute lung injury adolescent adult adult respiratory distress syndrome Article artificial ventilation blood gas body weight child childhood disease clinical protocol decision support system end tidal carbon dioxide tension female heart high frequency oscillatory ventilation human infant intensivist major clinical study male metarteriole national health organization newborn observational study oxygen saturation oxygenation positive end expiratory pressure ventilation priority journal prospective study protective ventilation pulse oximetry tertiary health care tidal volume adult respiratory distress syndrome artificial ventilation clinical decision making clinical practice clinical protocol decision support system practice guideline preschool child procedures protocol compliance standards statistics and numerical data United States
Objectives: Although pediatric intensivists philosophically embrace lung protective ventilation for acute lung injury and acute respiratory distress syndrome, we hypothesized that ventilator management varies. We assessed ventilator management by evaluating changes to ventilator settings in response to blood gases, pulse oximetry, or end-tidal Co2. We also assessed the potential impact that a pediatric mechanical ventilation protocol adapted from National Heart Lung and Blood Institute acute respiratory distress syndrome network protocols could have on reducing variability by comparing actual changes in ventilator settings to those recommended by the protocol. Design: Prospective observational study. Setting: Eight tertiary care U.S. PICUs, October 2011 to April 2012. Patients: One hundred twenty patients (age range 17 d to 18 yr) with acute lung injury/acute respiratory distress syndrome. Measurements and Main Results: Two thousand hundred arterial and capillary blood gases, 3,964 oxygen saturation by pulse oximetry, and 2,757 end-tidal Co2 values were associated with 3,983 ventilator settings. Ventilation mode at study onset was pressure control 60%, volume control 19%, pressure-regulated volume control 18%, and high-frequency oscillatory ventilation 3%. Clinicians changed Fio2 by ±5 or ±10% increments every 8 hours. Positive end-expiratory pressure was limited at ∼10 cm H2O as oxygenation worsened, lower than would have been recommended by the protocol. In the first 72 hours of mechanical ventilation, maximum tidal volume/kg using predicted versus actual body weight was 10.3 (8.5-12.9) (median [interquartile range]) versus 9.2 mL/kg (7.6- 12.0) (p < 0.001). Intensivists made changes similar to protocol recommendations 29% of the time, opposite to the protocol's recommendation 12% of the time and no changes 56% of the time. Conclusions: Ventilator management varies substantially in children with acute respiratory distress syndrome. Opportunities exist to minimize variability and potentially injurious ventilator settings by using a pediatric mechanical ventilation protocol offering adequately explicit instructions for given clinical situations. An accepted protocol could also reduce confounding by mechanical ventilation management in a clinical trial. © 2017 by the Society of Critical Care.

Metrics

4 Record Views

Details

Logo image